Manufacturer & applicator · Dubai, UAE

Cleaning and protection chemicals for heating and cooling systems.

Kuvars Chem develops, manufactures and applies specialty chemicals for HVAC, boiler and cooling tower systems. 11 products, 23 technical services, R&D since 2003.

AIR-COOLED CHILLER · DRAWINGKC-01 / 2026
Condenser coils fouledCoils cleaned: CLIMA CLEAR
Efficiency −34%Design capacity restored
Scale in evaporator circuitNANOSAFE X 300 protection
Before cleaningAfter cleaning and protection
Since 2003R&D and manufacturing
250+Projects delivered
11Specialty products
23Technical services

Who we are

We make the chemistry and we apply it.

Kuvars Chem is the international brand of Kuvars Kimya, a Turkish R&D manufacturer that has developed, produced and applied specialty chemicals for HVAC, boiler and cooling tower systems since 2003. Our laboratory in Ankara develops the formulations and our technical teams apply them. In the UAE, Kuvars Chem supplies and applies the products from Dubai.

Chemical production plant with laboratory, illustration

Develop

Formulations developed and tested in the Kuvars Kimya R&D laboratory.

Manufacture

Produced in the Ankara facility; a technical data sheet for every product.

Apply

Applied and documented by the Kuvars Chem technical team on site.

Five product groups, eleven formulations.

1 product

HVAC Cleaning

Alkaline chemistry for coils, chillers and air handling units.

3 products

Descaling & Neutralisation

Inhibitor-enhanced acidic descalers for exchangers, boilers and new installations, and the neutraliser that completes every cleaning.

5 products

Water Treatment & Protection

Molybdate- and phosphate-based corrosion and scale control for closed loops, steam boilers and cooling systems.

1 product

Microbial & Biofilm Control

Broad-spectrum biocide for cooling towers, process water and industrial circuits.

1 product

Leak Sealing & Waterproofing

Silicate-based sealing for micro-leaks in piping, pools, terraces and subfloors.

All 11 products

Find the right chemistry for your system

Start from the system and the problem you see. Every acidic cleaning ends with NANO CLEAN NR, and we put every cleaned loop on protective dosing.

System or problemProductNote
Fouled AC coils, AHU or fancoil surfaces (dust, oil, biofilm)CLIMA CLEARAlkaline coil cleaner, 1:3–1:10
Scale in copper, aluminium or mixed-metal exchangers, boilers, condenser tubesNANO CLEAN → NANO CLEAN NRInhibitor-enhanced descaler, then neutralisation
Scale and rust in steel or cast-iron boilers, steam generators, pipelinesNANO CLEAN 100 → NANO CLEAN NRIndustrial acidic cleaner, then neutralisation
New installation before start-upNANO CLEAN → NANO CLEAN NRTwo-step pre-commissioning flushing
Closed-loop heating, cooling or hot water circulation (no boiling)NANOSAFE XMolybdate-based, 0.3–0.6 L/m³, continuous
Steam boiler or steam generator, non-food-contact steamNANOSAFE X 100Molybdate-based, 0.3–0.6 L/m³; also closed-loop heating
Steam that may contact food or dairy productsNANOSAFE X 200 HALFormulated in compliance with FDA criteria, 0.3–0.5 L/m³
Chiller, AHU and fancoil water circuitsNANOSAFE X 300Phosphate-based three-in-one, 0.3–0.5 L/m³
Open-circuit cooling tower and tower-connected exchangers, heavy foulingNANOSAFE X 400 DCMolybdate-based dispersant, 0.2–0.4 L/m³, treated water
Bacteria, algae, biofilm in cooling towers and process waterNANOSAFE BIOCIDIsothiazolinone-based, shock or continuous
Micro-leaks in piping, pools, terraces, subfloorsWTR RESISTSilicate-based sealer, circulated

What cleaning and protection give you

Efficiency

Energy savings in the 10–40% range recorded on reference projects after chemical cleaning. US DOE data: 0.8 mm of iron- and silica-bearing boiler scale can raise fuel use by up to 7%.

Protection

Inhibitor-enhanced, metal-safe descaling (NANO CLEAN and NANO CLEAN NR) and molybdate- or phosphate-based post-treatment protection (NANOSAFE series) that keeps cleaned surfaces clean.

Compliance

NANOSAFE X 200 HAL formulated in compliance with FDA criteria for food and dairy steam. Technical data sheets for all 11 products. Dubai DET trade licence.

Accountability

One contact from site survey to work record. The technical team that specifies the product also applies it.

References

250+ projects in Turkey and Kazakhstan

City hospitals, air bases, airports, towers, malls and food plants. UAE projects under way.

PetlasHoffmann AluminiumRakhatBCC InvestTalan TowersTAIBorusanPladisEsentai MallInterContinental

All references by sector

Questions we get before the first order

Which descaler do I use for a copper-tube heat exchanger?

NANO CLEAN. It is the inhibitor-enhanced descaler for copper, aluminium, galvanised steel and mixed-metal systems. Use NANO CLEAN 100 for steel and cast-iron equipment. Every acidic cleaning is completed with NANO CLEAN NR.

Do I need NANO CLEAN NR after cleaning?

Yes. Acidic residues left in the system after descaling or flushing have to be neutralised before start-up and before discharge. NANO CLEAN NR restores system pH and is the last step of every chemical cleaning.

What is the difference between NANOSAFE X and NANOSAFE X 100?

NANOSAFE X is for closed-loop heating, cooling and hot water circulation systems that do not boil. NANOSAFE X 100 is formulated for steam boilers and steam generators and is also suitable for closed-loop heating systems. Where steam may contact food or dairy products, the product is NANOSAFE X 200 HAL.

Does NANOSAFE X 200 HAL meet food industry requirements?

It is formulated in compliance with FDA criteria for boiler water treatment in food and dairy applications. The technical data sheet states the formulation basis.

Which product goes into a cooling tower?

NANOSAFE X 400 DC for scale, dispersion and corrosion control in open-circuit cooling towers and tower-connected heat exchangers, on treated (softened) make-up water. NANOSAFE BIOCID for bacteria, algae and biofilm. NANOSAFE X 300 conditions the chiller, AHU and fancoil water circuits.

How much product does a closed loop need?

Typical continuous dosage for NANOSAFE X and NANOSAFE X 100 is 0.3–0.6 L/m³ of system volume, adjusted to water quality and operating conditions. Monitor hardness, conductivity and pH, and analyse the system water periodically.

All questions

Describe your system and we will review it.

Send the system type, metal, volume and the problem you see. Our technical team replies within 24 hours on business days.